Services

Our thermal imaging services

We show where heat escapes from your building, what it costs per heating season, and what to fix first. Seven services, two core packages, one approach: the product is the analysis, not the picture.

  • from HUF 190,000 (2D) · from HUF 390,000 (3D package)
  • Delivery: 10 working days
  • Net prices, + VAT
FIG. 01 IR · night survey

Illustrative example – not real measurement data.

01 / Overview

Seven services, one goal

Each answers the same question: where is the defect, what does it cost, and when is it worth fixing.

02 / Packages

Which package fits whom?

The services fall into two core packages and a few add-ons. Exact prices are on the pricing page.

Comparing the packages: who they suit, what they give, what they cost
2D quick diagnostic3D packageRoof / PV (drone)Annual programme
Suits One building or a few questionable spots; a quick decision is needed The whole facility; several decision makers; re-measuring after repairs Flat roof, hall roof, solar array Those who want to track the effect of repairs season after season
What it gives Annotated thermal images, A/B/C list, loss estimate in forints, PDF All of the 2D plus a 3D heat map, breakdown per building element, scenario table Thermal orthomosaic, coordinate-referenced defect map, PDF Winter survey + summer check + post-repair re-scan
Indicative price (net) from HUF 190,000 (≤ 1,000 m²; to 2,000 m² +70 Ft/m², max. HUF 260,000) from HUF 390,000 (≤ 1,500 m²; to 5,000 m² +110 Ft/m²) from HUF 140,000 (≤ 2,500 m²); add-on to a package HUF 110,000 from HUF 285,000 (2D-based), from HUF 585,000 (3D-based)
Season Late Oct – March, at night Late Oct – March, at night Spring to autumn; subject to airspace and permits Year-round
Meeting 45 minutes 60 minutes – Several per year

Add-ons: electrical cabinet screening HUF 12,000 per cabinet (with a package; stand-alone HUF 18,000, min. HUF 60,000); cold store / cellar module HUF 45,000 per room; pipe run HUF 60,000 per started 500 m (min. HUF 90,000); verification re-scan HUF 70,000. Travel from our base (Tiszavasvári) is free within 40 km, HUF 15,000 for 40–80 km, HUF 30,000 for 80–130 km.

Pioneer programme 2026/27: for the first 10 facilities the 2D quick diagnostic is HUF 135,000 and the 3D package HUF 275,000, in return for written consent to an anonymised case study and a feedback conversation. Limited to 10 facilities.

04 / How it goes

Night-time measurement, engineering analysis, a decision list

Every service follows the same chain.

  1. Step 1: Briefing

    Goals, drawings, operating pattern, choosing the night.

    1–2 days

  2. Step 2: On-site survey

    Night-time exterior and, as needed, interior thermal images, with measurement conditions recorded.

  3. Step 3: Registration and analysis

    Images placed on the (3D) model; location, size and estimated loss of each defect in W, kWh, m³ and forints.

  4. Step 4: Report and walkthrough

    PDF report, A/B/C action list, raw files; in the 3D package a browser-based 3D heat map. We go through the order together.

    10 working days

05 / Honestly

What our services cannot do

Good decisions need the limits too.

  • A thermal camera measures surface temperature. The forint value of a loss is an estimate, with a range and stated assumptions.
  • Not every hidden defect shows in a thermal image.
  • Savings only occur once repairs are carried out; we promise no guaranteed savings.
  • Not an energy performance certificate, not an energy audit, not the mandatory inspection of electrical installations, not a fire-safety inspection, not an accredited test.

06 / FAQ

What people ask about our services

Which package should I start with?
If the question is the heat loss of one building and what matters most is an itemised loss list in forints, the 2D quick diagnostic from HUF 190,000 is enough. If you want to understand the whole building, involve several people, or re-measure after repairs, the 3D package from HUF 390,000 is the better choice. Upgrading from 2D to 3D within 30 days costs HUF 200,000.
How do your services differ from an energy audit?
Statutory assessments (energy performance certificate, audit, electrical inspection) prove compliance and are carried out by professionals authorised under Hungarian law. We look for where the loss is and what it is worth in forints. The two complement each other. Our survey is an engineering thermal-imaging survey, not an accredited or certified inspection.
When can I order?
Exterior surveys in the heating season need measuring at night, from late autumn to March. Roofs, solar arrays, electrical cabinets and chilled rooms can also be measured in summer. If the night does not meet the conditions we reschedule free of charge (up to 2 times).
Do you work for private individuals?
No. We offer our services to businesses and organisations: halls, warehouses, shops, wineries, cold stores and institutions.

Request a quote for your facility

Tell us briefly how big and what kind of building it is. We reply within one working day and say which package fits. Requesting a quote commits you to nothing.