Public buildings · sports hall

Heating costs of a public building: what should you fix first?

The operator of a public building decides within a limited budget: the question is not what can be fixed, but what to fix first. A night-time thermal survey shows the biggest losses item by item in HUF, in priority order, so that decision preparation rests on numbers.
  • Fixed, known price
  • Quick diagnostic HUF 135,000 + VAT
  • A–B–C prioritised list

Illustrative example – not real measurement data.

01 / The situation

What comes with a public building?

  • 01

    Older, mixed building stock

    Parts of the building differ in age and condition, and renovations are partial. The thermal image shows where an element was left out and where an earlier repair failed.

  • 02

    Tall spaces, large glazing

    In a sports hall the warmth rises, and the roof and eaves lose it over a long run. Glazing frames are thermal bridges of their own.

  • 03

    Little budget, many wishes

    When each item has an estimated fix cost and payback, the repairs that give most can be chosen and the decision is easy to justify.

02 / What we typically find

What we typically find

Typical items in this type of facility. Which of them exist in your building is what the survey shows: we do not promise defects.

  • Roof, attic floor

    Missing or wet insulation, thermal bridges in the roof space and slab.

  • Windows, shutter boxes

    Windows that do not close, badly fitted frames, shutter-box thermal bridges.

  • Plinth, eaves, corners

    Thermal bridges where the structure stays cold.

  • Sports-hall roof and rooflights

    Gaps in a tall space, where the stack effect is strongest.

  • Boiler room, pipework, manifolds

    Uninsulated pipes, fittings and manifolds in the plant room.

  • Electrical distribution boards

    Screening of distribution boards for heating up under load.

03 / Worked example

What can an item like this be worth? Example, October 2026 prices

Example, October 2026 prices Estimate

The example: Workshop / small production hall. 40 x 25 m, 7 m high, 18 C, gas warm-air heaters, 1 roller door (4.0 x 4.5 m) + 1 sectional door (3.5 x 3.5 m), process extraction. Medium case: Both door seals poor, 25 m of wall-panel joint, 30 m2 wet roof, 30 m eaves thermal bridge.

Estimated loss per season, medium case
420,000 HUF
Estimate range: HUF 330,000–590,000
Cost of fixing all items
1,300,000 HUF
Estimate band: HUF 720,000–2,500,000
Payback if only the quick (A) items are fixed
12 mo
Estimate 3 items, ≈HUF 230,000/season saved
Survey price at the pilot rate, + VAT
135,000 HUF
list price: HUF 190,000
Defect cost per season at three levels HUF/season Estimate
  • Localised defects ≈ HUF 99,000

    2 items

  • Medium cluster ≈ HUF 420,000

    5 items

  • Widespread defects ≈ HUF 1,300,000

    6 items

Prio.ItemLossFixPayback
A Roller door: perimeter seals (13 m x 10 mm) ≈ HUF 65,000/season ≈ HUF 30,000 ≈6 mo
A Wall-panel joints (25 m x 2 mm) ≈ HUF 120,000/season ≈ HUF 110,000 ≈11 mo
A Sectional door: perimeter seals (13 m x 8 mm) ≈ HUF 50,000/season ≈ HUF 90,000 ≈22 mo
B Wet roof insulation (30 m2) ≈ HUF 170,000/season ≈ HUF 660,000 ≈48 mo

Heating cost of the fault-free baseline: ≈ HUF 5,300,000/season; the defects of the medium case add 7.3%.

Energy price basis: Hungarian business gas, net, 9 October 2026: central 40.4 Ft/kWh, range 32.1–56.9 Ft/kWh. The forward curve implies lower prices in the following years.

Estimate – not a guarantee. Figures are model-based and actual values may differ.

04 / Pilot offer

For the first 10 facilities: pilot prices for the 2026/27 heating season

Quick diagnostic

HUF 135,000 + VAT

list price: HUF 190,000 and up + VAT

  • Exterior and interior thermal imaging
  • Annotated thermal image catalogue
  • A–B–C findings list with HUF/season estimates
  • 10–15 page PDF, 45-minute walkthrough

3D package

HUF 275,000 + VAT

list price: HUF 390,000 and up + VAT

  • Everything in the Quick diagnostic
  • Interactive 3D heat map in your browser
  • Loss breakdown per building element
  • Action plan with payback, 60-minute meeting

Limited to the first 10 facilities. Quick diagnostic up to 2,000 m², 3D package up to 2,500 m²; travel within 80 km (free up to 40 km). Orders by 31 January 2027, surveys by 31 March 2027, weather permitting.

Our recommendation

What fits a public building?

For one building up to 2,000 m², the Quick diagnostic gives a tangible order of priorities. For several building blocks or complex building services the 3D package (pilot price up to 2,500 m²) is clearer. For several buildings on the same visit, the additional building costs 60% of the list price.

  • Electrical cabinet screening: HUF 12,000 per cabinet with a package (not a safety inspection)
  • Annual programme: winter survey, summer check and post-repair re-scan together

What we ask in return

  • Written consent to an anonymised case study (sector, size band, region; no name, logo or address). You approve the final text.
  • A 30-minute feedback interview, and a follow-up call after six months on which fixes were done.

Same scope and quality as a list-price order. The price does not depend on what you say in the feedback.

05 / How it works

Three steps from quote to fix list

  1. Step 1: Briefing and quote

    We ask about size, heating or cooling system and energy price. You get a fixed written quote.

    1 working day

  2. Step 2: Night-time survey

    We survey in the heating season, at night, outside teaching or opening hours. The caretaker or operator accompanies us indoors. We do not disturb use.

    on site

  3. Step 3: Report and walkthrough

    PDF report: for each item the location, likely cause, estimated loss with a range, fix suggestion and priority. Raw files and a walkthrough.

    10 working days

06 / Common questions

What people usually ask

Does it replace the mandatory energy documents?
No. The energy performance certificate and the audit are statutory documents prepared by an authorised professional. Our report complements them with the location and HUF value of the losses.
When do you survey, and does it disturb use?
In the heating season, at night. The interior walk-round is outside opening hours, so school or training schedules are not disturbed.
How do we place an order?
After your quote request we give a fixed price in writing. The invoice and contract are in the organisation's name; the order is for business purposes.

07 / Honest limits

What we do not do

  • The survey is not an energy performance certificate, not a statutory energy audit and does not replace statutory checks. It serves another purpose: showing the location and HUF value of the loss.
  • We do not prepare grant applications, designs or procurement documents; the report is decision-preparation data.
  • Savings materialise only after the fixes are done; we do not guarantee them.

08 / Get a quote

Request a quote for this type of facility

Tell us the type, location and approximate size of the facility. We reply by the next working day at the latest. The request is for business purposes: we serve companies and organisations.

E.g. what the issue is (high bills, draughts, damp …) and when a survey would suit you.

Condition: written consent to an anonymised case study and a short feedback conversation.